FINGER PULSE OXIMETER, CLINICALLY VALIDATED - LEPU (LOX100A)
FINGER PULSE OXIMETER, CLINICALLY VALIDATED - LEPU (LOX100A)
The pulse oximeter LEPU model LOX100A is used for the non-invasive measurement of arterial oxygen saturation (SpO₂), pulse frequency (PR) and perfusion index (PI).
Recommendation: buy only pulse oximeters with medical CE certificate, having as main benefit a correct measurement of oxygen concentration and pulse.
In this sense, you can check that the CE mark on the box is accompanied by a 4-digit number of the certification body or ask the seller to present you the opinion from the Ministry of Health (ANMDM) to be sure that the manufacturer meets the quality standards and that these pulse oximeters have the right to be legally sold on the Romanian market.
Features :
- can be used by both adults and children; if the child's fingers are too small, you can use the big toe from their foot
- the measurement is quick and precise and is carried out by emitting and receiving infrared rays
- CE certification as a class 2a medical device
- scope: families, hospitals, medical social organizations, physical care in sports, etc.
- 2-color OLED screen: for better data display
- the pulse oximeter model LOX100 has 4 display rotation directions: when the measurement is stable, pressing the power button will change the display direction
- easy to transport thanks to the compact shape
- it closes automatically in case of non-use for more than 8 seconds
- when the battery is discharged, the screen will display a low battery indicator and close after 8 seconds
- does not require calibration
- easy to use: put one of your fingers in the rubber hole of the pulse oximeter (as large an area as possible) with the surface of the nail pointing upwards, then release the clamp. Press the start button and the pulse oximeter will start working.
- operating temperature: 5℃ ~ 40℃
- storage temperature: -20 ℃~55℃
- weight : 60 grams (including batteries)
- power supply: 2 AAA batteries (included)
- autonomy : 25 hours
- material: ABS plastic
Display features:
- SpO2 value display
- PR pulse value display
- battery indicator
- perfusion index
- plestimogram
Technical specifications:
- SpO2 measurement ranges: 70%-99%
- accuracy: 80%~99% ±2%; 70%~79% ±3%; unspecified for below 70%
- resolution: ±1%
- PR pulse measurement range: 30 bpm~240 bpm
- accuracy: ±2 bpm or ±2%
- resolution: ±1bpm
- perfusion index range: 0.3%~20%
- power consumption : <30 mA
Package Included:
- pulse oximeter x 1 pc
- textile cord x 1 pc
- user manual
Product size: 6.9 x 3.5 x 2.9 cm
Warranty: 12 months +
Careful! This product is a medical device and does not fall under GEO 34/2014 art 3, paragraph 3, letter b, regarding the return of products. Read the instructions for use carefully. The device can only be used for the purpose mentioned in the instructions for use. Medical products are not toys. The device was designed for practical use, but it cannot replace a medical consultation. The pulse oximeter is NOT intended for diagnosis. In case of abnormal values displayed, please go to the hospital for a further examination. Even during prolonged periods of use, if you feel discomfort or pain in your finger, please remove the pulse oximeter immediately to prevent finger injury. Do not use the pulse oximeter in an MRI or CT environment. Never use abrasive cleaning materials, such as steel wool or metal polish. Do not let any liquid enter the product, and do not immerse parts of the device in any liquid. Avoid pouring liquid on the device when cleaning it. It is forbidden to leave the product directly exposed to sunlight, chemicals or high temperatures. SpO2 measurements can be negatively affected in the presence of high ambient light. Cover the sensor area to protect it from sunlight (with a surgical towel, for example) if necessary. Avoid using the equipment immediately after moving it from a warm environment to a warm, humid place. DANGER OF EXPLOSION – Do not use the pulse oximeter in a flammable atmosphere. The batteries should be removed from the compartment if the device will not be used for a long period of time.